Complete Set of CAMPUS® Data, ASTM Data, Biopolymer Database, Application Database, Tradename Database, Literature Database, Toolbox.

Material datasheets available free. Online registration at: www.materialdatacenter.com

Material Data Center is a leading international information system for the plastics industry. Material Data Center offers a comprehensive plastics database, calculation tools, CAE interfaces, a literature database and an application database. For more information about Material Data Center visit www.materialdatacenter.com.

This is the free Material Data Center Datasheet of Ultramid® A3X2G10 - PA66-GF50 FR(52) - BASF

Material Data Center offers the following functions for Ultramid® A3X2G10:
unit conversion, PDF datasheet print, comparison with other plastics, application examples, snap fit calculation, beam deflection calculation, parameters for material models, CAE Interfaces

Check here, which other Ultramid A datasheets, application examples or technical articles are available in Material Data Center

Use the following short links to get directly to the properties of interest in this datasheet:
Any use of this information falls under the rules of our disclaimer.
Product Texts
Glass fibre fibre reinforced injection moulding grade with improved flame retardance. Flame retardant based on red phosphorus; giving outstanding electrical properties and very high stiffness and strength.
Processing/Physical Characteristicsdry / condUnitTest Standard
ISO Data
Melt volume-flow rate, MVR 25 / * cm³/10min ISO 1133
Temperature 275 / * °C -
Load 5 / * kg -
Mechanical propertiesdry / condUnitTest Standard
ISO Data
Tensile Modulus 16000 / 12000 MPa ISO 527
Stress at break 180 / 130 MPa ISO 527
Strain at break 2 / 3 % ISO 527
Tensile creep modulus, 1000h * / 5400 MPa ISO 899-1
Charpy impact strength, +23°C 55 / 55 kJ/m² ISO 179/1eU
Charpy impact strength, -30°C 50 / - kJ/m² ISO 179/1eU
Charpy notched impact strength, +23°C 13 / 16 kJ/m² ISO 179/1eA
Charpy notched impact strength, -30°C 11 / - kJ/m² ISO 179/1eA
Thermal propertiesdry / condUnitTest Standard
ISO Data
Melting temperature, 10°C/min 260 / * °C ISO 11357-1/-3
Temp. of deflection under load, 1.80 MPa 250 / * °C ISO 75-1/-2
Temp. of deflection under load, 0.45 MPa 250 / * °C ISO 75-1/-2
Coeff. of linear therm. expansion, parallel 17 / * E-6/K ISO 11359-1/-2
Coeff. of linear therm. expansion, normal 66 / * E-6/K ISO 11359-1/-2
Burning Behav. at 1.5 mm nom. thickn. V-0 / * class IEC 60695-11-10
Thickness tested 1.6 / * mm -
Yellow Card available yes / * - -
Burning Behav. at thickness h V-2 / * class IEC 60695-11-10
Thickness tested 0.4 / * mm -
Yellow Card available yes / * - -
Burning Behav. 5V at thickness h 5VA / * class IEC 60695-11-20
Thickness tested 1.6 / * mm -
Yellow Card available yes / * - -
Oxygen index 27 / * % ISO 4589-1/-2
Electrical propertiesdry / condUnitTest Standard
ISO Data
Relative permittivity, 1MHz 3.6 / 5 - IEC 62631-2-1
Dissipation factor, 1MHz 200 / - E-4 IEC 62631-2-1
Volume resistivity 1E13 / 1E10 Ohm*m IEC 62631-3-1
Surface resistivity * / 1E13 Ohm IEC 62631-3-2
Electric strength 33 / 30 kV/mm IEC 60243-1
Comparative tracking index - / 600 - IEC 60112
Other propertiesdry / condUnitTest Standard
Water absorption 4 / * % Sim. to ISO 62
Humidity absorption 0.9 / * % Sim. to ISO 62
Density 1600 / - kg/m³ ISO 1183
Material specific propertiesdry / condUnitTest Standard
ISO Data
Viscosity number 140 / * cm³/g ISO 307, 1157, 1628
Diagrams
Viscosity-shear rate , Ultramid® A3X2G10, PA66-GF50 FR(52), BASF
Shearstress-shear rate , Ultramid® A3X2G10, PA66-GF50 FR(52), BASF
Dynamic Shear modulus-temperature , Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Stress-strain , Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Stress-strain , Ultramid® A3X2G10 (cond.), PA66-GF50 FR(52), BASF
Secant modulus-strain , Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Secant modulus-strain , Ultramid® A3X2G10 (cond.), PA66-GF50 FR(52), BASF
Stress-strain (isochronous) 23°C, Ultramid® A3X2G10 (cond.), PA66-GF50 FR(52), BASF
Creep modulus-time 23°C, Ultramid® A3X2G10 (cond.), PA66-GF50 FR(52), BASF
Creep curve 23°C, Ultramid® A3X2G10 (cond.), PA66-GF50 FR(52), BASF
Stress-strain (isochronous) 60°C, Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Creep modulus-time 60°C, Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Creep curve 60°C, Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Stress-strain (isochronous) 90°C, Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Creep modulus-time 90°C, Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Creep curve 90°C, Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Stress-strain (isochronous) 120°C, Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Creep modulus-time 120°C, Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Creep curve 120°C, Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Specific volume-temperature (pvT) , Ultramid® A3X2G10, PA66-GF50 FR(52), BASF
Tensile modulus-temperature , Ultramid® A3X2G10 (dry), PA66-GF50 FR(52), BASF
Tensile modulus-temperature , Ultramid® A3X2G10 (cond.), PA66-GF50 FR(52), BASF
Characteristics
Processing
Injection Molding
Delivery form
Pellets
Additives
Release agent
Special Characteristics
Flame retardant, Halogen-free, Heat stabilized or stable to heat
Regional Availability
Other text information
Injection molding
PREPROCESSING
Pre/Post-processing, max. allowed water content: .15 %
Pre/Post-processing, Pre-drying, Temperature: 80 - 100 °C
Pre/Post-processing, Pre-drying, Time: 4 h

PROCESSING
injection molding, Melt temperature, range: 290 - 300 °C
injection molding, Melt temperature, recommended: 295 °C
injection molding, Mold temperature, range: 80 - 90 °C
injection molding, Mold temperature, recommended: 85 °C
injection molding, Dwell time, thermoplastics: 10 min
Application examples
Housing, switch unit, washing machine
Disclaimer
Copyright Altair Engineering GmbH. Altair Engineering GmbH assumes no liability for the system to be free of errors. The user takes sole responsibility for the use of this data under the exclusion of every liability from Altair Engineering GmbH; this is especially valid for claims of compensation resulting from consequential damages. Altair explicitly points out that any decision about the application of materials must be double checked with the producer of this material. This includes all contents of this system. Copyright laws are applicable for the content of this system.
Created: Source: www.materialdatacenter.com


Material Data Center is provided by M-Base Engineering + Software GmbH. M-Base Engineering + Software GmbH assumes no liability for the system to be free of errors. Any decision about the application of materials must be double checked with the producer of this material.

Additional information about this material, like producer contact address, etc. can be found at www.materialdatacenter.com. For access to this extra information a registration is requested. Free online registration is available.